12. Performance Optimization: Node and Hardware Level

12.1 Persistence mode

Without persistence mode, the driver tears down GPU state when the last client exits, which adds seconds of latency to every pod start. The operator's driver container runs nvidia-persistenced, so this is on by default. Verify it:

kubectl exec -n gpu-operator ds/nvidia-driver-daemonset -- nvidia-smi -q | grep -i persistence

12.2 Clocks and power

# Inspect throttling
nvidia-smi -q -d PERFORMANCE,CLOCK,POWER

# Lock graphics clocks for consistent latency (inference / benchmarking)
nvidia-smi -lgc <min>,<max>
nvidia-smi -rgc                 # reset

# Power cap (perf/watt optimization; often -10–20% power costs only a few % perf)
nvidia-smi -pl <watts>
  • For throughput or cost per token: Try power capping. Many workloads are memory bound and lose little performance at lower power.
  • For latency-critical inference: Lock the clocks to avoid ramp-up jitter.
  • Apply these settings with a privileged DaemonSet or a node-tuning tool so they survive reboots. Use them carefully and document them.

12.3 Cooling and throttling

Check DCGM_FI_DEV_CLOCK_THROTTLE_REASONS. Constant HW_SLOWDOWN, HW_THERMAL, or SW_THERMAL events point to datacenter cooling or airflow problems. No software tuning fixes those.

12.4 ECC

Keep ECC enabled in production. Silent data corruption is far worse than the ~5–10% memory capacity and bandwidth cost on older GPUs. HBM GPUs have ECC with negligible overhead.

nvidia-smi topo -m
        GPU0  GPU1  GPU2  GPU3  NIC0  CPU Affinity  NUMA Affinity
GPU0     X    NV18  NV18  NV18  PXB   0-55          0
GPU1    NV18   X    NV18  NV18  PXB   0-55          0
...
Code Meaning Performance
NV# NVLink (# of links) Best
PIX Same PCIe switch Good
PXB Multiple PCIe switches OK
PHB Through the CPU host bridge Worse
NODE Across PCIe host bridges within a NUMA node Worse
SYS Across NUMA nodes (QPI/UPI/xGMI) Worst

Goals:

  • Multi-GPU jobs should get GPUs connected by NVLink/NVSwitch, or at least on the same PCIe switch.
  • CPU threads and memory should be on the same NUMA node as the GPU.
  • The RDMA NIC should be on the same PCIe switch as its GPU (PIX/PXB) for GPUDirect RDMA.

The NVIDIA device plugin prefers allocating topology-aligned GPU sets when a container asks for multiple GPUs. On NVSwitch systems (DGX/HGX) all GPUs are equal, so this matters mostly on PCIe servers.

12.6 Fabric Manager (NVSwitch systems)

HGX/DGX A100, H100, H200, and B200 systems with NVSwitch require Fabric Manager. The operator's driver container runs it automatically on these systems. If CUDA reports system not yet initialized (error 802), Fabric Manager isn't running or its version doesn't match the driver.

12.7 OS-level tuning

  • CPU governor: Set to performance.
  • Transparent hugepages: Settings vary by workload. Many ML stacks prefer madvise.
  • IOMMU: Use iommu=pt (passthrough) for bare-metal performance with RDMA.
  • PCIe ACS: Disable ACS on PCIe switches (or set it up correctly) for GPUDirect P2P/RDMA. Otherwise traffic goes through the root complex.
  • Kernel: Use an LTS kernel that the driver branch supports.